Contact Info

Peter Merian-Weg 12

Phone: +41 61 965 11 11

Web: www.straumann.com

Products & Solutions

Angel Moreno: All-Records-in-One® for immediate loading – a novel technique for manufacturing a full-arch, fixed, implant-supported provisional restoration in the surgical office (Straumann® Bone Level Tapered Implant)

By | March 20th, 2017|Dental Implants, Dental Prosthetics|

 

 

This case report presents an immediate-loading procedure as an innovative application for the newly described “All-Records-in-One®” impression technique*. This method allows us to fabricate a temporary implant-supported restoration for an edentulous patient in a quick, accurate and comfortable manner for both patients and clinicians. As the procedure is entirely prosthodontically driven, it is highly [...]

Straumann Connections 1/17: Straumann® PURE Ceramic Implant peer-to-peer surgical event in Boston

By | March 7th, 2017|Clinical Cases, Dental Implants, Education|

 

 

Together with Straumann, Drs. Paul Fugazzotto and Anya Rost partnered with their referring dentists and Dickerman Dental Laboratory to create a 5-day surgical peer-to-peer event in their practice near Boston. 28 Straumann PURE implants were placed using computer guided surgery, and were immediately restored with provisional crowns. THE STRAUMANN® PURE CERAMIC IMPLANT [...]

Why Straumann® Novaloc® is your solution for extremely reliable hybrid dentures

By | March 6th, 2017|Dental Prosthetics|

 

 

There are moments in life when you want a connection to be extremely reliable… So you are looking for a hybrid denture connection that is extremely reliable and durable. The problem: So far, existing attachment systems may have been facing their limits in challenging dental implant situations. In this infographic, you learn why the new Straumann® Novaloc® [...]

Michael Kristensen: Straumann® Bone Level Tapered Implant and augmentation with cerabone®, Jason® membrane and Emdogain® in daily practice

By | February 28th, 2017|Biomaterials, Clinical Cases, Dental Implants|

 

 

"Straumann® BLT implants in combination with botiss biomaterials (cerabone® and Jason® membrane) and Straumann Emdogain® made this challenging case uncomplicated, with only minimal patient discomfort after surgery and a very good esthetic result." Dr. Michael Kristensen PICTURE DOCUMENTATION INITIAL SITUATION The patient, a healthy 22-year-old male, has agenesis of 12 [...]

Martin Schimmel: A maxillary overdenture retained by four Straumann® Novaloc® abutments

By | February 23rd, 2017|Clinical Cases, Dental Prosthetics|

 

 

The patient was treated for recurrent failure of her fixed dental prosthesis over several years. She was very upset with her situation because she works as a sales assistant in a department store and relies on impeccable function and aesthetics of her dentition.  The female patient was 61 years old when she presented at [...]

Kay Vietor: The Straumann® Bone Level Tapered Implant ⌀2.9 mm in daily clinical practice

By | February 21st, 2017|Clinical Cases, Dental Implants|

 

 

“The Straumann® Bone Level Tapered Implant  ⌀2.9 mm represents an enrichment of my treatment portfolio that greatly simplifies the treatment procedures in cases with unfavorable narrow-space conditions often found in young patients.” Dr Kay Vietor PRODUCT INFORMATION FROM THE MANUFACTURER The "SmallOne" [Straumann® Bone Level Tapered Implant  ⌀2.9 mm] is specifically engineered to [...]

Leonardo Trombelli: Periodontal regeneration with the Single Flap Approach (Straumann® Emdogain)

By | February 16th, 2017|Clinical Cases, Dental Biomaterials, Education|

 

 

Periodontitis is the most common chronic inflammatory disease seen in humans. 5 – 15% of the worldwide population suffers from severe periodontitis that may lead to tooth loss [1]. Subjects with periodontitis have a 25% increased risk for coronary heart disease when compared to periodontitis-free individuals [2].  Over the years, many treatment strategies have [...]

Straumann® CARES® Scan & Shape: Turn into digital

By | January 24th, 2017|Dental Prosthetics, Digital Dentistry|

 

 

Straumann® CARES® Scan & Shape is a key component of Straumann® CARES® Digital Solutions. It is tailored to serve customers who need to outsource the design and manufacture of customized restorations.  A new comprehensive level of on-demand CAD/CAM design services for all cases. Dental labs are facing tremendous pressure from restorative dentists to deliver customized [...]

Herminio García: Replacement of the upper left central incisor with an immediate Straumann® Bone Level Tapered Implant and a customized abutment on a Straumann® Variobase® crown

By | January 20th, 2017|Clinical Cases, Dental Implants, Dental Prosthetics|

 

 

Immediate implant placement following tooth extraction might be a viable alternative to delayed placement. However, it requires careful case selection. The implant position and the available peri-implant soft tissue become increasingly important in a patient with a high lip line. This case report describes a surgical technique that preserves anterior esthetics, combining minimally invasive [...]

Sergio Piano: “With the Straumann® Pro Arch protocol, the patient is already reassured of the final result from the very beginning of the procedure”

By | January 19th, 2017|Dental Prosthetics, Interviews|

 

 

An interview with Dr. Sergio Piano, Italy. The “Straumann® Pro Arch” concept is an efficient and simple method to treat the edentulous patient with immediate loading, providing a rehabilitation that not only produces high-quality esthetic results but also proves cost-effective. This concept, supported by scientific literature, strongly focuses on the pre-operative planning, allowing for [...]